MATERIAL SAFETY DATA SHEET

Essentially Similar to U.S. Department of Labor Form OSHA

Revised: 01/20/2012

HMIS Health-1 Flammibility-2 Reactivity 0

SECTION I-Product Information

Manufacturer  Name: A.V.W. Inc.                          

24 Hour Emergency Phone Number: 800-424-9300

Product Name: Super Lubricant

 

SECTION II-Hazardous Ingredients

 

Carbon Dioxide                                     CAS#     12438-9                   TWA 10000           %   1-  5

Aliphatic Hydrocarbon                       CAS#     64742-96-7             TWA     200           % 40-55

Aliphatic Petroleum Naptha               CAS#     64742-30-9             TWA     200           % 40-55

SECTION III-Physical Data

Boiling Point:                                        UND

Specific Gravity                                    (H2O=1)=.80

Vapor Pressure (mm Hg):                    UND

Solubility in Water:                              Insoluble

Appearance:                                         Brown liquid with oil odor.

 

SECTION IV-Fire and Explosion Hazard Data

Flash Point:                                           131 F

Extinguishing Media:                          Water, CO2, Foam, Dry Chemical

Special Fire Fighting Procedures:      Do not expose containers to temperatures above 120 F.

Unusual Fire and Explosion:              NONE

SECTION V-Health Hazard and First Aid

Time Weighted Average (TWA):     200 ppm based in the raw material.

Carcinogen:                                           No

Acute Chronic Health Effects:           Excessive exposure may cause irritation to upper respiratory tract. Excessive exposure may cause carboxyhemoglobinemia, thereby impairing the bloods ability to transport oxygen.

Primary Routes of Entry:                     X Inhalation                          X Ingestion                           X Skin

Effects of Overexposure:                    Eyes-May cause pain, moderate eye irritation and slight corneal injury. Vapors may irritate eyes.

                                                                Skin-May cause irritation. Repeated contact may cause drying or flaking of skin.

                                                                Inhalation-In confined or poorly ventilated areas, vapors can readily accumulate and cause unconsciousness and death.

                                                                Ingestion-May be harmful.

First Aid:

                                                                Eyes-Flush with water for 15 minutes. Get medical attention if irritation persists.

                                                                Skin-Wash with soap and water.

                                                                Inhalation-Move to fresh air. Get medical attention.

                                                                Ingestion-Do not induce vomiting. Get medical attention immediately.

 

SECTION VI-Reactivity Data

Stability:                                                Stable X

Conditions to Avoid:                          Hydrolysis producing small amounts of hydrochloric acid possible with gross water contamination. Avoid open flames, welding arcs, or other high temperature sources, which induce thermal decomposition.

Incompatibility:                                    Strong oxidizers; caustics, chemically active metals such as aluminum, magnesium and sodium.

 

SECTION VII-Spill or Leak Procedures

Steps to take in case material is released or spilled: Use absorbent material and trash receptacle. Waste disposal method Federal and

Local regulations.

 

SECTION VIII-Special Protection Information

Respiratory Protection:                       Adequate Ventilation

Gloves (type):                                       None

Eye Protection:                                     Glasses (if required)

Other Protective Equipment:              None

 

SECTION IX-Special Precautions

Precautions to be taken in handling and storing: Read and follow all label directions. Do not store containers at temperatures above

120 F. Do not use near i32 ignition sources